Innovative
equipment for
liver examination
endocrinologists
5% of people suffer liver diseases and only 5% of them know about that. *Тарасова О.И., Кухарева Е.И., Красницкая С.К. и др. Оценка эффективности ультразвуковой сдвиговой эластометрии и стеатометрии печени. Терапевтический архив. 2020; 92 (4)
*ЗЛОКАЧЕСТВЕННЫЕ НОВООБРАЗОВАНИЯ В РОССИИ В 2020 ГОДУ (ЗАБОЛЕВАЕМОСТЬ И СМЕРТНОСТЬ) Под редакцией А.Д. КАПРИНА, В.В. СТАРИНСКОГО, А.О. ШАХЗАДОВОЙ Московский научно-исследовательский онкологический институт имени П.А. Герцена
According to figures provided by Russian Federal State Statistics Service more than 50000 people annually die of different liver diseases.
Flexibility
Accuracy
Safety
Cost recovery
Technology features
WFUMB and EFSUMB guidelines
Nondelay full report
Common method of examination
Features of monitoring
Transient Elastography
Transient Elastography (TE) is a new innovative technology. The unicity of the method is that minor mechanical vibrations promoting transverse waves to hepatic tissue allow to cover the volume of measurement 100-200 times larger than the volume taken by biopsy. Estimation and measurement of tissue compliance is proceeded by ultrasound technology. Specific combined mechanical and ultrasound probe is used. Due to the mechanical wave with the preset parameters generated by this probe, we receive clinical accuracy of 97%.
Instant and accurate result
the official distributor of iLivTouch in Russia
Compare technologies
Systems
This absolutely non-invasive technology of revealing and estimating the hepatopathy helps in receiving:
- quantitative data of hepatic fibrosis state
- quantitative data of hepatic steatosis state
Advantages of
transient elastometry method
Flexibility
- flexibility of examination probe for all kind of patients: children, men and women
of standard body constitution and patients with obesity - accurate data for diagnosing the early state of disease
- the possibility to use the system for conducted therapy monitoring and for evaluation of its efficiency.
- no extra charges for system applying
- examination takes max 5 minutes
Accuracy
- the only system with the accuracy of 97%
- examination reproducibility at the reinvestigation of the same patient with variation of results no more than 3%
- WFUMB and EFSUMB (World and European Federations For Ultrasound In Medicine And Biology) recommendations, standards and recommendations of FASL (European Association for
the Study of the Liver) in applying Transient Elastography (TE) for checkups and discriminatory diagnosis. - Volume of measurement 100-200 times larger than the volume taken by biopsy
Safety
- due to noninvasiveness patients more like to have examination
- compared to biopsy is a common method of examination in the USA, Europe and China that is economically and commercially viable
- scale of quality of the conducted examination and plausibility of measurements IQR maximally protects the operator from mistakes
- technology is fully standardized and maximally independent from operator that helps to lower requirements for operator’s qualification
- volume of measurement is entirely hepatic tissues that helps to lower the percentage of false-positive and negative results
Simplicity
- no extra charges
- examination takes max 5 minutes
- Automatic and nondelay report on F1-F4 parameters for estimating the fibrosis state according to METAVIR scale with an estimation of fatty liver syndrome
the official distributor of iLivTouch in Russia
iLivTouch in action
Announce the immediacy of the problem
We'll assist you with social advertising to help and improve people's quality of life.
Reconsideration of examination methods
02Lack of efficacy of examination methods leads to rising death from liver diseases rates.
Buy iLivTouch
We provide primary and constant further training for doctors.
Primary diagnostics
04Primary diagnostics and division patients into groups (average flow of patients is 500 people a month).
Verification
Any diagnosis should be verified by MRI / CT.
Consulting and treatment
06Consultation of the hepathologist and treatment.
Patients health gain
Improvement of statistics of liver diseases in Russia.
Repeated diagnostics
08Diagnostics with iLivTouch is necessary for dynamics of treatment observation.